Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
2.
JMIR Form Res ; 8: e50035, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38691395

RESUMEN

BACKGROUND: Wrist-worn inertial sensors are used in digital health for evaluating mobility in real-world environments. Preceding the estimation of spatiotemporal gait parameters within long-term recordings, gait detection is an important step to identify regions of interest where gait occurs, which requires robust algorithms due to the complexity of arm movements. While algorithms exist for other sensor positions, a comparative validation of algorithms applied to the wrist position on real-world data sets across different disease populations is missing. Furthermore, gait detection performance differences between the wrist and lower back position have not yet been explored but could yield valuable information regarding sensor position choice in clinical studies. OBJECTIVE: The aim of this study was to validate gait sequence (GS) detection algorithms developed for the wrist position against reference data acquired in a real-world context. In addition, this study aimed to compare the performance of algorithms applied to the wrist position to those applied to lower back-worn inertial sensors. METHODS: Participants with Parkinson disease, multiple sclerosis, proximal femoral fracture (hip fracture recovery), chronic obstructive pulmonary disease, and congestive heart failure and healthy older adults (N=83) were monitored for 2.5 hours in the real-world using inertial sensors on the wrist, lower back, and feet including pressure insoles and infrared distance sensors as reference. In total, 10 algorithms for wrist-based gait detection were validated against a multisensor reference system and compared to gait detection performance using lower back-worn inertial sensors. RESULTS: The best-performing GS detection algorithm for the wrist showed a mean (per disease group) sensitivity ranging between 0.55 (SD 0.29) and 0.81 (SD 0.09) and a mean (per disease group) specificity ranging between 0.95 (SD 0.06) and 0.98 (SD 0.02). The mean relative absolute error of estimated walking time ranged between 8.9% (SD 7.1%) and 32.7% (SD 19.2%) per disease group for this algorithm as compared to the reference system. Gait detection performance from the best algorithm applied to the wrist inertial sensors was lower than for the best algorithms applied to the lower back, which yielded mean sensitivity between 0.71 (SD 0.12) and 0.91 (SD 0.04), mean specificity between 0.96 (SD 0.03) and 0.99 (SD 0.01), and a mean relative absolute error of estimated walking time between 6.3% (SD 5.4%) and 23.5% (SD 13%). Performance was lower in disease groups with major gait impairments (eg, patients recovering from hip fracture) and for patients using bilateral walking aids. CONCLUSIONS: Algorithms applied to the wrist position can detect GSs with high performance in real-world environments. Those periods of interest in real-world recordings can facilitate gait parameter extraction and allow the quantification of gait duration distribution in everyday life. Our findings allow taking informed decisions on alternative positions for gait recording in clinical studies and public health. TRIAL REGISTRATION: ISRCTN Registry 12246987; https://www.isrctn.com/ISRCTN12246987. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2021-050785.

3.
Res Sq ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38559043

RESUMEN

Progressive gait impairment is common in aging adults. Remote phenotyping of gait during daily living has the potential to quantify gait alterations and evaluate the effects of interventions that may prevent disability in the aging population. Here, we developed ElderNet, a self-supervised learning model for gait detection from wrist-worn accelerometer data. Validation involved two diverse cohorts, including over 1,000 participants without gait labels, as well as 83 participants with labeled data: older adults with Parkinson's disease, proximal femoral fracture, chronic obstructive pulmonary disease, congestive heart failure, and healthy adults. ElderNet presented high accuracy (96.43 ± 2.27), specificity (98.87 ± 2.15), recall (82.32 ± 11.37), precision (86.69 ± 17.61), and F1 score (82.92 ± 13.39). The suggested method yielded superior performance compared to two state-of-the-art gait detection algorithms, with improved accuracy and F1 score (p < 0.05). In an initial evaluation of construct validity, ElderNet identified differences in estimated daily walking durations across cohorts with different clinical characteristics, such as mobility disability (p < 0.001) and parkinsonism (p < 0.001). The proposed self-supervised gait detection method has the potential to serve as a valuable tool for remote phenotyping of gait function during daily living in aging adults.

4.
Mov Disord ; 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38486430

RESUMEN

BACKGROUND: Cueing can alleviate freezing of gait (FOG) in people with Parkinson's disease (PD), but using the same cues continuously in daily life may compromise effectiveness. Therefore, we developed the DeFOG-system to deliver personalized auditory cues on detection of a FOG episode. OBJECTIVES: We aimed to evaluate the effects of DeFOG during a FOG-provoking protocol: (1) after 4 weeks of DeFOG-use in daily life against an active control group; (2) after immediate DeFOG-use (within-group) in different medication states. METHOD: In this randomized controlled trial, 63 people with PD and daily FOG were allocated to the DeFOG or active control group. Both groups received feedback on their daily living step counts using the device, but the DeFOG group also received on-demand cueing. Video-rated FOG severity was compared pre- and post-intervention through a FOG-provoking protocol administered at home off and on-medication, but without using DeFOG. Within-group effects were tested by comparing FOG during the protocol with and without DeFOG. RESULTS: DeFOG-use during the 4 weeks was similar between groups, but we found no between-group differences in FOG-severity. However, the within-group analysis showed that FOG was alleviated by DeFOG (effect size d = 0.57), regardless of medication state. Combining DeFOG and medication yielded an effect size of d = 0.67. CONCLUSIONS: DeFOG reduced FOG considerably in a population of severe freezers both off and on medication. Nonetheless, 4 weeks of DeFOG-use in daily life did not ameliorate FOG during the protocol unless DeFOG was worn. These findings suggest that on-demand cueing is only effective when used, similar to other walking aids. © 2024 International Parkinson and Movement Disorder Society.

5.
ERJ Open Res ; 10(2)2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38444656

RESUMEN

Introduction: The clinical validity of real-world walking cadence in people with COPD is unsettled. Our objective was to assess the levels, variability and association with clinically relevant COPD characteristics and outcomes of real-world walking cadence. Methods: We assessed walking cadence (steps per minute during walking bouts longer than 10 s) from 7 days' accelerometer data in 593 individuals with COPD from five European countries, and clinical and functional characteristics from validated questionnaires and standardised tests. Severe exacerbations during a 12-month follow-up were recorded from patient reports and medical registries. Results: Participants were mostly male (80%) and had mean±sd age of 68±8 years, post-bronchodilator forced expiratory volume in 1 s (FEV1) of 57±19% predicted and walked 6880±3926 steps·day-1. Mean walking cadence was 88±9 steps·min-1, followed a normal distribution and was highly stable within-person (intraclass correlation coefficient 0.92, 95% CI 0.90-0.93). After adjusting for age, sex, height and number of walking bouts in fractional polynomial or linear regressions, walking cadence was positively associated with FEV1, 6-min walk distance, physical activity (steps·day-1, time in moderate-to-vigorous physical activity, vector magnitude units, walking time, intensity during locomotion), physical activity experience and health-related quality of life and negatively associated with breathlessness and depression (all p<0.05). These associations remained after further adjustment for daily steps. In negative binomial regression adjusted for multiple confounders, walking cadence related to lower number of severe exacerbations during follow-up (incidence rate ratio 0.94 per step·min-1, 95% CI 0.91-0.99, p=0.009). Conclusions: Higher real-world walking cadence is associated with better COPD status and lower severe exacerbations risk, which makes it attractive as a future prognostic marker and clinical outcome.

6.
Sci Rep ; 14(1): 1754, 2024 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-38243008

RESUMEN

This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and - 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application.Trial registration: ISRCTN - 12246987.


Asunto(s)
Velocidad al Caminar , Dispositivos Electrónicos Vestibles , Humanos , Anciano , Marcha , Caminata , Proyectos de Investigación
7.
IEEE Trans Biomed Eng ; 71(3): 1076-1083, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37862272

RESUMEN

OBJECTIVE: Postural control naturally declines with age, leading to an increased risk of falling. Within clinical settings, the deployment of balance assessments has become commonplace, facilitating the identification of postural instability and targeted interventions to forestall falls among older adults. Some studies have ventured beyond the controlled laboratory, leaving, however, a gap in our understanding of balance in real-world scenarios. METHODS: Previously reported algorithms were used to build a finite-state machine (FSM) with four states: walking, turning, sitting, and standing. The FSM was validated against video annotations (gold standard) in an independent dataset with data collected on 20 older adults. Later, the FSM was applied to data from 168 community-dwelling older people in the InCHIANTI cohort who were evaluated both in the laboratory and then remotely in real-world conditions for a week. A 70/30 data split with recursive feature selection and resampling techniques was used to train and test four machine-learning models. RESULTS: In identifying fallers, duration, distance, and mean frequency computed during standing in real-world settings revealed significant relationships with fall risk. Also, the best-performing model (Lasso Regression) built on real-world balance features had a higher area under the curve (AUC, 0.76) than one built on lab-based assessments (0.57). CONCLUSION: Real-world balance features differ considerably from laboratory balance assessments (Romberg test) and have a higher predictive capacity for identifying patients at high risk of falling. SIGNIFICANCE: These findings highlight the need to move beyond traditional laboratory-based balance measures and develop more sensitive and accurate methods for predicting falls.


Asunto(s)
Aprendizaje Automático , Caminata , Humanos , Anciano , Equilibrio Postural
8.
Front Neurol ; 14: 1247532, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909030

RESUMEN

Introduction: The clinical assessment of mobility, and walking specifically, is still mainly based on functional tests that lack ecological validity. Thanks to inertial measurement units (IMUs), gait analysis is shifting to unsupervised monitoring in naturalistic and unconstrained settings. However, the extraction of clinically relevant gait parameters from IMU data often depends on heuristics-based algorithms that rely on empirically determined thresholds. These were mainly validated on small cohorts in supervised settings. Methods: Here, a deep learning (DL) algorithm was developed and validated for gait event detection in a heterogeneous population of different mobility-limiting disease cohorts and a cohort of healthy adults. Participants wore pressure insoles and IMUs on both feet for 2.5 h in their habitual environment. The raw accelerometer and gyroscope data from both feet were used as input to a deep convolutional neural network, while reference timings for gait events were based on the combined IMU and pressure insoles data. Results and discussion: The results showed a high-detection performance for initial contacts (ICs) (recall: 98%, precision: 96%) and final contacts (FCs) (recall: 99%, precision: 94%) and a maximum median time error of -0.02 s for ICs and 0.03 s for FCs. Subsequently derived temporal gait parameters were in good agreement with a pressure insoles-based reference with a maximum mean difference of 0.07, -0.07, and <0.01 s for stance, swing, and stride time, respectively. Thus, the DL algorithm is considered successful in detecting gait events in ecologically valid environments across different mobility-limiting diseases.

9.
Age Ageing ; 52(10)2023 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-37897807

RESUMEN

The Task Force on Global Guidelines for Falls in Older Adults has put forward a fall risk stratification tool for community-dwelling older adults. This tool takes the form of a flowchart and is based on expert opinion and evidence. It divides the population into three risk categories and recommends specific preventive interventions or treatments for each category. In this commentary, we share our insights on the design, validation, usability and potential impact of this fall risk stratification tool with the aim of guiding future research.


Asunto(s)
Accidentes por Caídas , Vida Independiente , Humanos , Anciano , Accidentes por Caídas/prevención & control , Medición de Riesgo
10.
ERJ Open Res ; 9(5)2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37753279

RESUMEN

Background: Gait characteristics are important risk factors for falls, hospitalisations and mortality in older adults, but the impact of COPD on gait performance remains unclear. We aimed to identify differences in gait characteristics between adults with COPD and healthy age-matched controls during 1) laboratory tests that included complex movements and obstacles, 2) simulated daily-life activities (supervised) and 3) free-living daily-life activities (unsupervised). Methods: This case-control study used a multi-sensor wearable system (INDIP) to obtain seven gait characteristics for each walking bout performed by adults with mild-to-severe COPD (n=17; forced expiratory volume in 1 s 57±19% predicted) and controls (n=20) during laboratory tests, and during simulated and free-living daily-life activities. Gait characteristics were compared between adults with COPD and healthy controls for all walking bouts combined, and for shorter (≤30 s) and longer (>30 s) walking bouts separately. Results: Slower walking speed (-11 cm·s-1, 95% CI: -20 to -3) and lower cadence (-6.6 steps·min-1, 95% CI: -12.3 to -0.9) were recorded in adults with COPD compared to healthy controls during longer (>30 s) free-living walking bouts, but not during shorter (≤30 s) walking bouts in either laboratory or free-living settings. Double support duration and gait variability measures were generally comparable between the two groups. Conclusion: Gait impairment of adults with mild-to-severe COPD mainly manifests during relatively long walking bouts (>30 s) in free-living conditions. Future research should determine the underlying mechanism(s) of this impairment to facilitate the development of interventions that can improve free-living gait performance in adults with COPD.

11.
J Parkinsons Dis ; 13(6): 999-1009, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37545259

RESUMEN

BACKGROUND: Real-world walking speed (RWS) measured using wearable devices has the potential to complement the Movement Disorder Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS III) for motor assessment in Parkinson's disease (PD). OBJECTIVE: Explore cross-sectional and longitudinal differences in RWS between PD and older adults (OAs), and whether RWS was related to motor disease severity cross-sectionally, and if MDS-UPDRS III was related to RWS, longitudinally. METHODS: 88 PD and 111 OA participants from ICICLE-GAIT (UK) were included. RWS was evaluated using an accelerometer at four time points. RWS was aggregated within walking bout (WB) duration thresholds. Between-group-comparisons in RWS between PD and OAs were conducted cross-sectionally, and longitudinally with mixed effects models (MEMs). Cross-sectional association between RWS and MDS-UPDRS III was explored using linear regression, and longitudinal association explored with MEMs. RESULTS: RWS was significantly lower in PD (1.04 m/s) in comparison to OAs (1.10 m/s) cross-sectionally. RWS significantly decreased over time for both cohorts and decline was more rapid in PD by 0.02 m/s per year. Significant negative relationship between RWS and the MDS-UPDRS III only existed at a specific WB threshold (30 to 60 s, ß= - 3.94 points, p = 0.047). MDS-UPDRS III increased significantly by 1.84 points per year, which was not related to change in RWS. CONCLUSION: Digital mobility assessment of gait may add unique information to quantify disease progression remotely, but further validation in research and clinical settings is needed.


Asunto(s)
Enfermedad de Parkinson , Humanos , Anciano , Enfermedad de Parkinson/complicaciones , Enfermedad de Parkinson/diagnóstico , Estudios Transversales , Gravedad del Paciente , Índice de Severidad de la Enfermedad , Modelos Lineales
12.
J Neuroeng Rehabil ; 20(1): 78, 2023 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-37316858

RESUMEN

BACKGROUND: Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. METHODS: Twenty healthy older adults, 20 people with Parkinson's disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. RESULTS: We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms' performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. CONCLUSIONS: Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms' performances. Trial registration ISRCTN - 12246987.


Asunto(s)
Tecnología Digital , Fracturas Femorales Proximales , Humanos , Anciano , Marcha , Caminata , Velocidad al Caminar , Modalidades de Fisioterapia
13.
Front Bioeng Biotechnol ; 11: 1143248, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37214281

RESUMEN

Introduction: Accurately assessing people's gait, especially in real-world conditions and in case of impaired mobility, is still a challenge due to intrinsic and extrinsic factors resulting in gait complexity. To improve the estimation of gait-related digital mobility outcomes (DMOs) in real-world scenarios, this study presents a wearable multi-sensor system (INDIP), integrating complementary sensing approaches (two plantar pressure insoles, three inertial units and two distance sensors). Methods: The INDIP technical validity was assessed against stereophotogrammetry during a laboratory experimental protocol comprising structured tests (including continuous curvilinear and rectilinear walking and steps) and a simulation of daily-life activities (including intermittent gait and short walking bouts). To evaluate its performance on various gait patterns, data were collected on 128 participants from seven cohorts: healthy young and older adults, patients with Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease, congestive heart failure, and proximal femur fracture. Moreover, INDIP usability was evaluated by recording 2.5-h of real-world unsupervised activity. Results and discussion: Excellent absolute agreement (ICC >0.95) and very limited mean absolute errors were observed for all cohorts and digital mobility outcomes (cadence ≤0.61 steps/min, stride length ≤0.02 m, walking speed ≤0.02 m/s) in the structured tests. Larger, but limited, errors were observed during the daily-life simulation (cadence 2.72-4.87 steps/min, stride length 0.04-0.06 m, walking speed 0.03-0.05 m/s). Neither major technical nor usability issues were declared during the 2.5-h acquisitions. Therefore, the INDIP system can be considered a valid and feasible solution to collect reference data for analyzing gait in real-world conditions.

14.
Sci Data ; 10(1): 38, 2023 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-36658136

RESUMEN

Wearable devices are used in movement analysis and physical activity research to extract clinically relevant information about an individual's mobility. Still, heterogeneity in protocols, sensor characteristics, data formats, and gold standards represent a barrier for data sharing, reproducibility, and external validation. In this study, we aim at providing an example of how movement data (from the real-world and the laboratory) recorded from different wearables and gold standard technologies can be organized, integrated, and stored. We leveraged on our experience from a large multi-centric study (Mobilise-D) to provide guidelines that can prove useful to access, understand, and re-use the data that will be made available from the study. These guidelines highlight the encountered challenges and the adopted solutions with the final aim of supporting standardization and integration of data in other studies and, in turn, to increase and facilitate comparison of data recorded in the scientific community. We also provide samples of standardized data, so that both the structure of the data and the procedure can be easily understood and reproduced.

15.
J Neuroeng Rehabil ; 19(1): 141, 2022 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-36522646

RESUMEN

BACKGROUND: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. METHODS: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants' strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson's disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. RESULTS: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. CONCLUSIONS: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. TRIAL REGISTRATION: ISRCTN-12246987.


Asunto(s)
Marcha , Enfermedad de Parkinson , Adulto , Humanos , Caminata , Velocidad al Caminar , Proyectos de Investigación
16.
Phys Ther ; 102(12)2022 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-36179090

RESUMEN

OBJECTIVE: Freezing of gait (FOG) is an episodic, debilitating phenomenon that is common among people with Parkinson disease. Multiple approaches have been used to quantify FOG, but the relationships among them have not been well studied. In this cross-sectional study, we evaluated the associations among FOG measured during unsupervised daily-living monitoring, structured in-home FOG-provoking tests, and self-report. METHODS: Twenty-eight people with Parkinson disease and FOG were assessed using self-report questionnaires, percentage of time spent frozen (%TF) during supervised FOG-provoking tasks in the home while off and on dopaminergic medication, and %TF evaluated using wearable sensors during 1 week of unsupervised daily-living monitoring. Correlations between those 3 assessment approaches were analyzed to quantify associations. Further, based on the %TF difference between in-home off-medication testing and in-home on-medication testing, the participants were divided into those responding to Parkinson disease medication (responders) and those not responding to Parkinson disease medication (nonresponders) in order to evaluate the differences in the other FOG measures. RESULTS: The %TF during unsupervised daily living was mild to moderately correlated with the %TF during a subset of the tasks of the in-home off-medication testing but not the on-medication testing or self-report. Responders and nonresponders differed in the %TF during the personal "hot spot" task of the provoking protocol while off medication (but not while on medication) but not in the total scores of the self-report questionnaires or the measures of FOG evaluated during unsupervised daily living. CONCLUSION: The %TF during daily living was moderately related to FOG during certain in-home FOG-provoking tests in the off-medication state. However, this measure of FOG was not associated with self-report or FOG provoked in the on-medication state. These findings suggest that to fully capture FOG severity, it is best to assess FOG using a combination of all 3 approaches. IMPACT: These findings suggest that several complementary approaches are needed to provide a complete assessment of FOG severity.


Asunto(s)
Trastornos Neurológicos de la Marcha , Enfermedad de Parkinson , Dispositivos Electrónicos Vestibles , Humanos , Enfermedad de Parkinson/tratamiento farmacológico , Enfermedad de Parkinson/complicaciones , Autoinforme , Estudios Transversales , Marcha
17.
Front Digit Health ; 4: 912353, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35873348

RESUMEN

The photoplethysmographic (PPG) signal has been applied in various research fields, with promising results for its future clinical application. However, there are several sources of variability that, if not adequately controlled, can hamper its application in pervasive monitoring contexts. This study assessed and characterized the impact of several sources of variability, such as physical activity, age, sex, and health state on PPG signal quality and PPG waveform parameters (Rise Time, Pulse Amplitude, Pulse Time, Reflection Index, Delta T, and DiastolicAmplitude). We analyzed 31 24 h recordings by as many participants (19 healthy subjects and 12 oncological patients) with a wristband wearable device, selecting a set of PPG pulses labeled with three different quality levels. We implemented a Multinomial Logistic Regression (MLR) model to evaluate the impact of the aforementioned factors on PPG signal quality. We then extracted six parameters only on higher-quality PPG pulses and evaluated the influence of physical activity, age, sex, and health state on these parameters with Generalized Linear Mixed Effects Models (GLMM). We found that physical activity has a detrimental effect on PPG signal quality quality (94% of pulses with good quality when the subject is at rest vs. 9% during intense activity), and that health state affects the percentage of available PPG pulses of the best quality (at rest, 44% for healthy subjects vs. 13% for oncological patients). Most of the extracted parameters are influenced by physical activity and health state, while age significantly impacts two parameters related to arterial stiffness. These results can help expand the awareness that accurate, reliable information extracted from PPG signals can be reached by tackling and modeling different sources of inaccuracy.

18.
Front Bioeng Biotechnol ; 10: 868928, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35721859

RESUMEN

There is growing interest in the quantification of gait as part of complex motor tasks. This requires gait events (GEs) to be detected under conditions different from straight walking. This study aimed to propose and validate a new marker-based GE detection method, which is also suitable for curvilinear walking and step negotiation. The method was first tested against existing algorithms using data from healthy young adults (YA, n = 20) and then assessed in data from 10 individuals from the following five cohorts: older adults, chronic obstructive pulmonary disease, multiple sclerosis, Parkinson's disease, and proximal femur fracture. The propagation of the errors associated with GE detection on the calculation of stride length, duration, speed, and stance/swing durations was investigated. All participants performed a variety of motor tasks including curvilinear walking and step negotiation, while reference GEs were identified using a validated methodology exploiting pressure insole signals. Sensitivity, positive predictive values (PPV), F1-score, bias, precision, and accuracy were calculated. Absolute agreement [intraclass correlation coefficient ( I C C 2,1 )] between marker-based and pressure insole stride parameters was also tested. In the YA cohort, the proposed method outperformed the existing ones, with sensitivity, PPV, and F1 scores ≥ 99% for both GEs and conditions, with a virtually null bias (<10 ms). Overall, temporal inaccuracies minimally impacted stride duration, length, and speed (median absolute errors ≤1%). Similar algorithm performances were obtained for all the other five cohorts in GE detection and propagation to the stride parameters, where an excellent absolute agreement with the pressure insoles was also found ( I C C 2,1 = 0.817 -   0.999 ). In conclusion, the proposed method accurately detects GE from marker data under different walking conditions and for a variety of gait impairments.

19.
Front Bioeng Biotechnol ; 10: 873202, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35433647

RESUMEN

Walking speed is an important clinical parameter because it sums up the ability to move and predicts adverse outcomes. However, usually measured inside the clinics, it can suffer from poor ecological validity. Wearable devices such as global positioning systems (GPS) can be used to measure real-world walking speed. Still, the accuracy of GPS systems decreases in environments with poor sky visibility. This work tests a solution based on a mass-market, real-time kinematic receiver (RTK), overcoming such limitations. Seven participants walked a predefined path composed of tracts with different sky visibility. The walking speed was calculated by the RTK and compared with a reference value calculated using an odometer and a stopwatch. Despite tracts with totally obstructed visibility, the correlation between the receiver and the reference system was high (0.82 considering all tracts and 0.93 considering high-quality tracts). Similarly, a Bland Altman analysis showed a minimal detectable change of 0.12 m/s in the general case and 0.07 m/s considering only high-quality tracts. This work demonstrates the feasibility and validity of the presented device for the measurement of real-world walking speed, even in tracts with high interference. These findings pave the way for clinical use of the proposed device to measure walking speed in the real world, thus enabling digital remote monitoring of locomotor function. Several populations may benefit from similar devices, including older people at a high risk of fall, people with neurological diseases, and people following a rehabilitation intervention.

20.
BMJ Open ; 11(12): e050785, 2021 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-34857567

RESUMEN

INTRODUCTION: Existing mobility endpoints based on functional performance, physical assessments and patient self-reporting are often affected by lack of sensitivity, limiting their utility in clinical practice. Wearable devices including inertial measurement units (IMUs) can overcome these limitations by quantifying digital mobility outcomes (DMOs) both during supervised structured assessments and in real-world conditions. The validity of IMU-based methods in the real-world, however, is still limited in patient populations. Rigorous validation procedures should cover the device metrological verification, the validation of the algorithms for the DMOs computation specifically for the population of interest and in daily life situations, and the users' perspective on the device. METHODS AND ANALYSIS: This protocol was designed to establish the technical validity and patient acceptability of the approach used to quantify digital mobility in the real world by Mobilise-D, a consortium funded by the European Union (EU) as part of the Innovative Medicine Initiative, aiming at fostering regulatory approval and clinical adoption of DMOs.After defining the procedures for the metrological verification of an IMU-based device, the experimental procedures for the validation of algorithms used to calculate the DMOs are presented. These include laboratory and real-world assessment in 120 participants from five groups: healthy older adults; chronic obstructive pulmonary disease, Parkinson's disease, multiple sclerosis, proximal femoral fracture and congestive heart failure. DMOs extracted from the monitoring device will be compared with those from different reference systems, chosen according to the contexts of observation. Questionnaires and interviews will evaluate the users' perspective on the deployed technology and relevance of the mobility assessment. ETHICS AND DISSEMINATION: The study has been granted ethics approval by the centre's committees (London-Bloomsbury Research Ethics committee; Helsinki Committee, Tel Aviv Sourasky Medical Centre; Medical Faculties of The University of Tübingen and of the University of Kiel). Data and algorithms will be made publicly available. TRIAL REGISTRATION NUMBER: ISRCTN (12246987).


Asunto(s)
Esclerosis Múltiple , Enfermedad de Parkinson , Dispositivos Electrónicos Vestibles , Anciano , Marcha , Humanos , Proyectos de Investigación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...